Platform ( INN650D140A ) |
Test Items | Test Conditions | Sample Size (Unit x Lot) | #Fail | Result |
HTRB |
T=150°C, VDS= 520V, 1000hrs |
77 x 3 |
0 Fail |
Pass |
HTGB |
T=150°C, VGS= 6.5V, 1000hrs |
77 x 3 |
0 Fail |
Pass |
TC |
-55 to +150°C, Air, 1000Cys |
77 x 3 |
0 Fail |
Pass |
HAST |
T=130°C, RH=85%, VDS=100V, 96hrs |
77 x 3 |
0 Fail |
Pass |
H3TRB |
T=85°C, RH=85%, VDS=520V, 1000hrs |
77 x 3 |
0 Fail |
Pass |
MSL3 |
T=30°C, RH=60%, 3 x reflow, 192hrs |
25 x 3 |
0 Fail |
Pass |
HBM |
All Pins |
3 x 1 |
0 Fail |
Class 2 |
CDM |
All Pins |
3 x 1 |
0 Fail |
Class C3 |
HTOL(QR-PFC) |
Tj=125°C, Input: 90 Vac, Output: 20V/6.5A, F=120KHz(QR)/100KHz(PFC) |
10 x 3 |
0 Fail |
Pass |
Spin-off Product( INN650D190A)
|
Test Items | Test Conditions |
Sample Size/Product
(Unit x Lot)/Product
| #Fail | Result |
HTRB |
T=150°C, VDS= 520V, 168hrs |
77 x 1 |
0 Fail |
Pass |
HTGB |
T=150°C, VGS= 6.5V, 168hrs |
77 x 1 |
0 Fail |
Pass |
TC |
-55 to +150°C, Air, 1000Cys |
77 x 1 |
0 Fail |
Pass |
HAST |
T=130°C, RH=85%, VDS=100V, 96hrs |
77 x 1 |
0 Fail |
Pass |
H3TRB |
T=85°C, RH=85%, VDS=520V, 1000hrs |
77 x 1 |
0 Fail |
Pass |
MSL3 |
T=30°C, RH=60%, 3 x reflow, 192hrs |
25 x 1 |
0 Fail |
Pass |